494 research outputs found

    Bioresorbable Polylactide Interbody Implants in an Ovine Anterior Cervical Discectomy and Fusion Model: Three-Year Results

    Get PDF
    Study Design. In vivo study of anterior discectomy and fusion using a bioresorbable 70:30 poly(l-lactide-co-d,l-lactide) interbody implant in an ovine model. Objective. To evaluate the efficacy of the polylactide implant to function as an interbody fusion device, and to assess the tissue reaction to the material during the resorption process. Summary of Background Data. The use of polylactide as a cervical interbody implant has several potential advantages when compared with traditional materials. Having an elastic modulus very similar to bone minimizes the potential for stress shielding, and as the material resorbs additional loading is transferred to the developing fusion mass. Although preclinical and clinical studies have demonstrated the suitability of polylactide implants for lumbar interbody fusion, detailed information on cervical anterior cervical discectomy and fusion (ACDF) with polylactide devices is desirable. Methods. Single level ACDF was performed in 8 skeletally mature ewes. Bioresorbable 70:30 poly (l-lactide-co-d,l-lactide) interbody implants packed with autograft were used with single-level metallic plates. Radiographs were made every 3 months up to 1 year, and yearly thereafter. The animals were killed at 6 months (3 animals), 12 months (3 animals), and 36 months (2 animals). In addition to the serial plain radiographs, the specimens were evaluated by nondestructive biomechanical testing and undecalcified histologic analysis. Results. The bioresorbable polylactide implants were effective in achieving interbody fusion. The 6-month animals appeared fused radiographically and biomechanically, whereas histologic sections demonstrated partial fusion (in 3 of 3 animals). Radiographic fusion was confirmed histologically and biomechanically at 12 months (3 of 3 animals) and 36 months (2 of 2 animals). A mild chronic inflammatory response to the resorbing polylactide implant was observed at both 6 months and 12 months. At 36 months, the operative levels were solidly fused and the implants were completely resorbed. No adverse tissue response was observed in any animal at any time period. Conclusion. Interbody fusion was achieved using bioresorbable polylactide implants, with no evidence of implant collapse, extrusion, or adverse tissue response to the material. The use of polylactide as a cervical interbody device appears both safe and effective based on these ACDF animal model results

    Major surgery induces acute changes in measured DNA methylation associated with immune response pathways

    Get PDF
    Surgery is an invasive procedure evoking acute inflammatory and immune responses that can influence risk for postoperative complications including cognitive dysfunction and delirium. Although the specific mechanisms driving these responses have not been well-characterized, they are hypothesized to involve the epigenetic regulation of gene expression. We quantified genome-wide levels of DNA methylation in peripheral blood mononuclear cells (PBMCs) longitudinally collected from a cohort of elderly patients undergoing major surgery, comparing samples collected at baseline to those collected immediately post-operatively and at discharge from hospital. We identified acute changes in measured DNA methylation at sites annotated to immune system genes, paralleling changes in serum-levels of markers including C-reactive protein (CRP) and Interleukin 6 (IL-6) measured in the same individuals. Many of the observed changes in measured DNA methylation were consistent across different types of major surgery, although there was notable heterogeneity between surgery types at certain loci. The acute changes in measured DNA methylation induced by surgery are relatively stable in the post-operative period, generally persisting until discharge from hospital. Our results highlight the dramatic alterations in gene regulation induced by invasive surgery, primarily reflecting upregulation of the immune system in response to trauma, wound healing and anaesthesia.This article is freely available via Open Access. Click on the Publisher URL to access it via the publisher's site.This work was supported by the Medical Research Council (Grant MR/M008924/1), the Sasakawa Foundation (Butterfield Awards B108) and the UK National Institute for Health Research (NIHR) Exeter Clinical Research Facility (Exeter CRF).Published version, Accepted version, Submitted versio

    A focused telephonic nursing intervention delivers improved adherence to A1c testing

    Get PDF
    Compliance with hemoglobin A1c (A1c) testing is suboptimal despite the clear national recommendations and guidelines established for care of patients with diabetes. Recent studies have demonstrated a relationship between participation in a diabetes disease management (DM) program and improved adherence to A1c testing. A focused intervention study was initiated to investigate the ability of a DM program to drive improvement in A1c testing. A cohort of 36,327 members experienced a statistically significant increase (29%) in A1c testing while participating in the 6-month focused intervention. This finding demonstrated that a focused DM intervention is able to deliver improvement in a clinical process metric critical for managing patients with diabetes, thereby reducing their risk of disease exacerbation

    Assessment of Surgical Procedural Time, Pedicle Screw Accuracy, and Clinician Radiation Exposure of a Novel Robotic Navigation System Compared With Conventional Open and Percutaneous Freehand Techniques: A Cadaveric Investigation

    Get PDF
    STUDY DESIGN: Cadaveric study. OBJECTIVE: To evaluate accuracy, radiation exposure, and surgical time of a new robotic-assisted navigation (RAN) platform compared with freehand techniques in conventional open and percutaneous procedures. METHODS: Ten board-certified surgeons inserted 16 pedicle screws at T10-L5 (n = 40 per technique) in 10 human cadaveric torsos. Pedicle screws were inserted with (1) conventional MIS technique (L2-L5, patient left pedicles), (2) MIS RAN (L2-L5, patient right pedicles), (3) conventional open technique (T10-L1, patient left pedicles), and (4) open RAN (T10-L1, patient right pedicles). Output included (1) operative time, (2) number of fluoroscopic images, and (3) screw accuracy. RESULTS: In the MIS group, compared with the freehand technique, RAN allowed for use of larger screws (diameter: 6.6 ± 0.6 mm vs 6.3 ± 0.5 mm; length: 50.3 ± 4.1 mm vs 46.9 ± 3.5 mm), decreased the number of breaches \u3e2 mm (0 vs 7), fewer fluoroscopic images (0 ± 0 vs 108.3 ± 30.9), and surgical procedure time per screw (3.6 ± 0.4 minutes vs 7.6 ± 2.0 minutes) (all CONCLUSION: RAN significantly improved accuracy and decreased radiation exposure in comparison to freehand techniques in both conventional open and percutaneous surgical procedures in cadavers. RAN significantly increased setup time compared with both conventional procedures

    Association between frequency of telephonic contact and clinical testing for a large, geographically diverse diabetes disease management population

    Get PDF
    Diabetes disease management (DM) programs strive to promote healthy behaviors, including obtaining hemoglobin A1c (A1c) and low-density lipoprotein (LDL) tests as part of standards of care. The purpose of this study was to examine the relationship between frequency of telephonic contact and A1c and LDL testing rates. A total of 245,668 members continuously enrolled in diabetes DM programs were evaluated for performance of an A1c or LDL test during their first 12 months in the programs. The association between the number of calls a member received and clinical testing rates was examined. Members who received four calls demonstrated a 24.1% and 21.5% relative increase in A1c and LDL testing rates, respectively, compared to members who received DM mailings alone. Response to the telephonic intervention as part of the diabetes DM programs was influenced by member characteristics including gender, age, and disease burden. For example, females who received four calls achieved a 27.7% and 23.6% increase in A1c and LDL testing, respectively, compared to females who received mailings alone; by comparison, males who were called achieved 21.2% and 19.9% relative increase in A1c and LDL testing, respectively, compared to those who received mailings alone. This study demonstrates a positive association between frequency of telephonic contact and increased performance of an A1c or LDL test in a large, diverse diabetes population participating in DM programs. The impact of member characteristics on the responsiveness to these programs provides DM program designers with knowledge for developing strategies to promote healthy behaviors and improve diabetes outcomes

    Multi-Messenger Gravitational Wave Searches with Pulsar Timing Arrays: Application to 3C66B Using the NANOGrav 11-year Data Set

    Get PDF
    When galaxies merge, the supermassive black holes in their centers may form binaries and, during the process of merger, emit low-frequency gravitational radiation in the process. In this paper we consider the galaxy 3C66B, which was used as the target of the first multi-messenger search for gravitational waves. Due to the observed periodicities present in the photometric and astrometric data of the source of the source, it has been theorized to contain a supermassive black hole binary. Its apparent 1.05-year orbital period would place the gravitational wave emission directly in the pulsar timing band. Since the first pulsar timing array study of 3C66B, revised models of the source have been published, and timing array sensitivities and techniques have improved dramatically. With these advances, we further constrain the chirp mass of the potential supermassive black hole binary in 3C66B to less than (1.65±0.02)×109 M(1.65\pm0.02) \times 10^9~{M_\odot} using data from the NANOGrav 11-year data set. This upper limit provides a factor of 1.6 improvement over previous limits, and a factor of 4.3 over the first search done. Nevertheless, the most recent orbital model for the source is still consistent with our limit from pulsar timing array data. In addition, we are able to quantify the improvement made by the inclusion of source properties gleaned from electromagnetic data to `blind' pulsar timing array searches. With these methods, it is apparent that it is not necessary to obtain exact a priori knowledge of the period of a binary to gain meaningful astrophysical inferences.Comment: 14 pages, 6 figures. Accepted by Ap

    Remote physiological monitoring: Clinical, financial, and behavioral outcomes in a heart failure population

    Get PDF
    This article reports on the outcomes associated with remote physiological monitoring (RPM) conducted as part of a heart failure disease management program. Claims data, medical records, data transmission records, and survey results for 91 individuals ages 50–92 (mean 74 years) successfully completing a heart failure RPM program were analyzed for time periods before, during, and after the monitoring intervention. The program was associated with significant reductions in per member per month costs and emergency room and hospital utilization. More detailed analyses were performed for specific gender and age subgroups. Participant surveys indicated high levels of satisfaction, and improvements in self-perceived health status, self-efficacy, and self-management behaviors. This study is the first to assess the impact of a RPM program following removal of the monitoring equipment. The results indicate that RPM, as a component of a traditional disease management program, has a sustained, beneficial effect on participants’ lifestyles after the monitoring period has ended
    corecore